Calor Autogas

Filling instructions

Filling Nozzles

UK Autogas refuelling nozzles use the bayonet style connection. There are two main types of
filling nozzles used in the UK - Gas Guard™ and De Visser™. Always ensure that which ever nozzle you use has a protective nozzle.

_

Gas Guard™ nozzle filling instructions

Gas Guard™ nozzle filling instructions

 

Ensure GasGuard™ nozzles are fitted with protective nozzle shields. Report to site staff if missing. (Nozzle shields have been removed from picture for clarity)

Connecting

1. Push nozzle over the lugs on the filler valve and turn barrel quarter turn clockwise to lock. Do not squeeze lever before nozzle is connected.

From this moment onwards ensure hands are away from the nozzle barrel.

2. Pull back lever and latch into place. Ensure lever is latched securely. Follow instructions on dispenser to commence dispensing.

Disconnecting

Ensure hands are away from the nozzle barrel.

3. When dispensing has ended, squeeze back lever and release latch. Release lever fully. A small release of gas will occur as you release the lever. This is normal!

Do not place hands on barrel until after the gas has released.


4. Turn barrel anti clockwise quarter turn to release nozzle from vehicle. Replace nozzle in holder on dispenser.

_

De Visser™ nozzle filling instructions

De Visser™ nozzle filling instructions


Ensure De Visser™ nozzles are fitted with protective nozzle shields. Report to site staff if missing.

Connecting

1. Hold the hose behind the nozzle and the guard, keeping lever pushed forward with the handle at
12 o’clock position.

Locate the nozzle over the lugs on the filler valve and turn the lever quarter turn clockwise to lock.

From this moment ensure hands are away from the nozzle barrel.

2. Pull back lever towards hose and latch into place. Ensure lever is latched securely. Follow instructions on dispenser to commence dispensing.

Disconnecting

Ensure hands are away from the nozzle barrel.

3. Hold hose behind guard and release lever by pushing forward. A small release of gas will occur as
you release the lever. This is normal!

4. Turn leaver anti clockwise quarter turn to release nozzle from vehicle. Replace nozzle in holder on dispenser.

_